Hydrothermal Autoclave OPX-281

Hydrothermal Autoclave OPX-281

  • By RISHI SETH
  • October 4, 2026
  • 0 Comment

The OPXICA OPX-281 Hydrothermal Autoclave is a 100 mL high-pressure laboratory reactor designed for hydrothermal and solvothermal synthesis. Featuring SS 316 construction, a cylindrical jacketed design, and compatibility with specialized liners, it supports controlled synthesis of nanoparticles, crystals, catalysts, chemicals, and advanced materials in research applications.

×

Product Inquiry

Fill out the form below and we will get back to you.

    SKU: OPX-281 Category:

    Description

    Model Number: OPX-281
    Product Name: Hydrothermal Autoclave
    Brand Name: OPXICA
    Chamber Capacity: 100 mL

    The OPXICA OPX-281 Hydrothermal Autoclave is a high-pressure laboratory reactor designed for hydrothermal and solvothermal synthesis under controlled temperature and pressure conditions. Manufactured with a robust SS 316 outer vessel, it is suitable for research involving chemical synthesis, nanoparticles, catalysts, crystals, advanced materials, and other compatible laboratory processes.

    Technical Specifications

    Parameter Specification
    Model Number OPX-281
    Product Name Hydrothermal Autoclave
    Brand Name OPXICA
    Product Type Hydrothermal / High-Pressure Reactor
    Chamber Volume 100 mL
    Maximum Temperature 230°C*
    Maximum Pressure 3 MPa*
    Vessel Material SS 316
    Outer Shell SS 316
    Heating Type Jacketed
    Shape Cylindrical
    Reactor Configuration Threaded Type
    Available Capacity Range 10 mL to 2000 mL
    Liner Options PTFE (Teflon) / PPL
    PTFE Maximum Temperature Up to 220°C
    PTFE Recommended Safe Limit 200°C
    PPL Maximum Temperature Up to 280°C
    PPL Recommended Safe Limit 260°C
    Application Hydrothermal & Solvothermal Research
    Typical Use Chemical, Nanoparticle, Catalyst & Crystal Synthesis
    Recommended Filling Not More Than 90% of Vessel Capacity

    *The usable temperature and pressure must follow the limits of the complete reactor configuration, including the liner and manufacturer-rated operating conditions.

    Key Features

    • 100 mL chamber capacity
    • Heavy-duty SS 316 outer construction
    • Designed for hydrothermal and solvothermal reactions
    • Maximum specified pressure up to 3 MPa
    • Cylindrical, compact laboratory configuration
    • Jacketed reactor construction
    • Available with PTFE (Teflon) or PPL liner options
    • Suitable for elevated-temperature laboratory synthesis
    • Designed for high-pressure reaction environments
    • Threaded closure design for smaller-capacity reactors
    • Suitable for nanoparticle and nanomaterial synthesis
    • Useful for catalyst and crystal preparation
    • Suitable for research and development laboratories
    • Available in multiple capacities for different research requirements
    • Designed for controlled scientific and material-synthesis applications

    Hydrothermal & Solvothermal Research

    The OPX-281 is designed for hydrothermal and solvothermal synthesis, where compatible chemical reactions are carried out in a sealed vessel under elevated temperature and pressure.

    These techniques are widely used in materials science and research for producing or studying nanomaterials, crystalline compounds, catalysts, ceramics, and other advanced materials under controlled laboratory conditions.

    SS 316 Construction

    The outer reactor vessel is manufactured from SS 316 stainless steel, providing robust mechanical construction for laboratory applications. The stainless-steel outer jacket surrounds and supports the inner reaction chamber.

    The actual chemical compatibility of the reactor depends on the liner material, reagents, temperature, pressure, concentration, and complete reactor configuration.

    PTFE (Teflon) Lined Reactor

    The PTFE-lined configuration is intended for compatible hydrothermal applications requiring chemical resistance. Based on the supplied specifications, the PTFE liner has a stated maximum temperature of approximately 220°C, with a recommended safe working limit of 200°C.

    Operating limits should always follow the rating supplied with the specific liner and complete reactor assembly.

    PPL Lined Reactor

    For applications requiring higher temperature capability, a PPL-lined configuration may be used where compatible with the intended process.

    According to the supplied specifications, PPL liners can support temperatures up to approximately 280°C, with a recommended working limit of around 260°C, subject to the rating of the actual reactor configuration.

    Available Capacity Range

    The Hydrothermal Autoclave series can be supplied in multiple capacities depending on laboratory requirements.

    Threaded Type: Typically available from 10 mL to 500 mL.

    Flange Type: Larger configurations may be available in 1 L, 1.5 L, and 2 L capacities.

    The OPX-281 featured here has a 100 mL chamber capacity.

    Working Purpose

    The OPXICA OPX-281 Hydrothermal Autoclave provides a sealed reaction environment for compatible laboratory synthesis requiring elevated temperature and pressure. It is particularly useful in research involving material formation and chemical transformations that require hydrothermal or solvothermal conditions.

    Researchers can use this type of reactor for applications involving nanoparticle synthesis, crystal growth, catalyst development, materials research, and chemical synthesis, provided the process remains within the rated limits of the reactor and liner.

    Applications

    The OPX-281 is suitable for:

    • Hydrothermal synthesis
    • Solvothermal synthesis
    • Nanoparticle research
    • Nanomaterial synthesis
    • Crystal growth studies
    • Catalyst synthesis
    • Materials science research
    • Chemical research
    • Advanced material development
    • Academic research laboratories
    • Research and development facilities
    • Institutional laboratories
    • Compatible industrial R&D
    • Quality-control and analytical research

    Laboratory Safety & Operating Considerations

    Because a hydrothermal autoclave operates under elevated temperature and pressure, it should only be operated by trained laboratory personnel according to the manufacturer’s operating manual and institutional safety procedures.

    The reactor, liner, seals, threads, and closure components should be inspected before operation. Do not exceed the rated temperature, pressure, or filling limits of the specific assembly. The supplied guidance recommends keeping the filling level at 90% or less; some reactions may require a lower limit, so the validated procedure and manufacturer instructions should take priority.

    The reactor should be allowed to cool and depressurize fully according to the manufacturer’s procedure before opening. Proper cleaning between compatible experiments is important to minimize contamination.

    At the End

    The OPXICA OPX-281 Hydrothermal Autoclave provides a specialized solution for scientific research involving elevated-temperature and elevated-pressure reactions. Its 100 mL chamber, SS 316 construction, and compatibility with specialized inner liners support a broad range of hydrothermal and solvothermal research applications.

    For reliable operation, users should always follow the specified limits for the particular reactor body, liner, seals, temperature, pressure, and chemical system being used.

    Frequently Asked Questions (FAQs)

    1. What is the OPXICA OPX-281 Hydrothermal Autoclave?

    The OPX-281 is a 100 mL high-pressure laboratory reactor designed for hydrothermal and solvothermal research applications.

    2. What is the capacity of the OPX-281?

    The specified chamber volume is 100 mL.

    3. What is the maximum specified temperature?

    The supplied specification lists a maximum temperature of 230°C for the reactor. However, the allowable operating temperature can be lower depending on the liner and complete reactor configuration.

    4. What is the maximum pressure?

    The supplied specification states a maximum pressure of 3 MPa. Users must remain within the rated limits of the specific assembled reactor.

    5. What material is used for the outer vessel?

    The reactor uses SS 316 stainless-steel construction for the specified outer vessel and shell.

    6. What types of liners are available?

    Hydrothermal reactors can be supplied with PTFE (Teflon) or PPL liners, depending on the intended operating conditions.

    7. What is the temperature limit of a PTFE liner?

    According to the supplied information, the PTFE liner has a maximum temperature of approximately 220°C, with a recommended safe working limit of around 200°C.

    8. What is the temperature limit of a PPL liner?

    The supplied information specifies a maximum temperature of approximately 280°C and a recommended safe limit of around 260°C for PPL.

    9. What is hydrothermal synthesis?

    Hydrothermal synthesis is a laboratory technique in which compatible materials undergo reactions in a sealed environment under elevated temperature and pressure.

    10. Can the OPX-281 be used for nanoparticle synthesis?

    Yes. Nanoparticle and nanomaterial synthesis are common research applications for compatible hydrothermal reactor systems.

    11. Can it be used for crystal synthesis?

    Yes. Hydrothermal reactors are commonly used in compatible crystal-growth and crystalline-material research.

    12. Can the reactor be used for catalyst research?

    Yes. The OPX-281 can support compatible research involving catalyst synthesis and materials development.

    13. What shape is the OPX-281?

    The reactor has a cylindrical configuration.

    14. What type of heating configuration is specified?

    The supplied specification describes the unit as having a jacketed heating configuration.

    15. Is the OPX-281 suitable for research institutions?

    Yes. It is intended for research laboratories, universities, scientific institutions, R&D facilities, and compatible industrial research applications.

    16. What is the recommended maximum filling level?

    The supplied information states that the reactor should not be filled beyond 90% of its capacity. The validated procedure or manufacturer may specify a lower limit for particular reactions.

    17. Are other capacities available?

    Yes. Hydrothermal reactor configurations are available in capacities ranging from approximately 10 mL to 2000 mL, depending on design and requirements.

    18. What is the difference between threaded and flange configurations?

    Smaller reactors are commonly supplied with threaded closures, while larger-capacity systems may use bolted flange arrangements. The exact configuration depends on reactor capacity and design.

    19. Can corrosive chemicals be used?

    Chemical compatibility depends on the liner, seals, concentration, temperature, pressure, and specific chemical involved. Compatibility should be verified before use rather than assuming the reactor is suitable for every corrosive material.

    20. Why choose the OPXICA OPX-281?

    The OPXICA OPX-281 combines a compact 100 mL chamber, SS 316 construction, specialized liner options, and a high-pressure reactor design for hydrothermal, solvothermal, nanoparticle, catalyst, crystal, and advanced materials research.

    RISHI SETH

    I’m a Digital Marketer and SEO Specialist focused on the Science & Research ecosystem. My niche expertise includes Microscope SEO, Laboratory Equipment SEO, Scientific Instrument SEO, and Research-focused SEO. I specialize in SEO, AEO, GEO & AIO—helping science-driven brands improve search visibility, build authority, reach researchers and laboratories, and stay discoverable across Google and AI-powered search.

    Leave a Reply

    Your email address will not be published. Required fields are marked *