Description
Technical Specifications
| Specification | Details |
|---|---|
| Product Name | Horizontal Laminar Air Flow Cabinet |
| Internal Model No. | OPX-HLAF Series |
| Product Type | Horizontal Clean Air Workstation |
| Construction | Heavy-Duty Fabricated Steel Cabinet |
| Outer Body | Powder-Coated Mild Steel |
| Work Surface | Stainless Steel SS-304 |
| Airflow Type | Horizontal Laminar Airflow |
| Main Filter | HEPA Filter (99.97% Efficiency at 0.3 Micron) |
| Pre Filter | Washable Synthetic Pre Filter |
| Air Velocity | 0.3–0.5 m/s |
| Blower | Low Noise Centrifugal Blower |
| Lighting | LED Illumination |
| UV Lamp | Optional |
| Noise Level | ≤65 dB |
| Front Panel | Transparent Acrylic / Toughened Glass |
| Power Supply | 220–230V AC, 50 Hz |
| Electrical Socket | Optional |
| Display | Digital Controller (Optional) |
| Usage/Application | Microbiology, Pharmaceutical, Biotechnology, Electronics & Research Laboratories |
| Compliance | Manufactured as per Standard Laboratory Equipment Practices |
Features
- Horizontal HEPA-filtered airflow for clean working conditions
- HEPA filter efficiency of 99.97% at 0.3 micron
- Washable pre-filter extends HEPA filter life
- Stainless steel SS-304 work surface
- Low-noise centrifugal blower
- Uniform airflow distribution
- Bright LED working illumination
- Durable powder-coated steel construction
- Energy-efficient operation
- Available in multiple chamber sizes
Benefits
- Protects samples from airborne contamination
- Improves accuracy of sterile laboratory procedures
- Provides clean working conditions for sensitive applications
- Reduces maintenance through efficient filtration
- Long service life with durable construction
- Supports continuous laboratory operation
- Excellent investment for pharmaceutical and research laboratories
Available Variants
| Working Chamber Size |
|---|
| 2′ × 2′ × 2′ |
| 3′ × 2′ × 2′ |
| 4′ × 2′ × 2′ |
| 6′ × 2′ × 2′ |
Optional Configurations
- UV Sterilization Lamp
- Digital Airflow Indicator
- Differential Pressure Gauge
- Magnehelic Pressure Gauge
- SS-304 Complete Interior
- Electrical Utility Socket
- Gas & Vacuum Utility Fittings
- Digital Microprocessor Controller
- Customized Chamber Dimensions
- Export Voltage Configuration
Applications
- Microbiology Laboratories
- Biotechnology Research
- Pharmaceutical Manufacturing
- Tissue Culture Laboratories
- Cell Culture Applications
- Medical Research Laboratories
- Electronics Assembly
- Food Testing Laboratories
- Quality Control Laboratories
- Universities & Research Institutes
Why Choose Our Products
- Precision-manufactured clean air workstations
- Premium HEPA filtration for dependable clean-air performance
- Durable laboratory-grade construction
- Multiple standard and customized configurations
- Reliable technical support and bulk supply capability
Frequently Asked Questions
What is a Horizontal Laminar Air Flow Cabinet used for?
A Horizontal Laminar Air Flow Cabinet provides a clean, particle-free working environment for handling sterile materials, microbiological samples, tissue cultures, pharmaceuticals, and laboratory research where contamination control is essential.
How does a horizontal laminar airflow cabinet work?
The cabinet draws air through a pre-filter and HEPA filter before delivering clean horizontal airflow across the work surface. This continuous airflow helps prevent airborne particles from contaminating laboratory samples.
What is the efficiency of the HEPA filter?
The standard HEPA filter provides approximately 99.97% filtration efficiency at 0.3 micron, making it suitable for clean laboratory applications.
Can UV sterilization be supplied?
Yes. UV sterilization lamps are available as an optional feature for chamber decontamination when the cabinet is not in operation.
Is the cabinet suitable for pharmaceutical laboratories?
Yes. It is widely used in pharmaceutical production, biotechnology research, microbiology laboratories, hospitals, tissue culture facilities, and research institutions requiring clean-air working conditions.
Can customized chamber sizes be manufactured?
Yes. Customized chamber dimensions, utility fittings, airflow monitoring systems, controller options, and voltage configurations can be supplied according to laboratory requirements.
How should the HEPA filter be maintained?
The pre-filter should be cleaned regularly, while the HEPA filter should be replaced according to operating hours, airflow performance, and laboratory maintenance schedules.
Do you supply Laminar Air Flow Cabinets in bulk?
Yes. Bulk orders are available for universities, pharmaceutical companies, hospitals, research institutes, biotechnology laboratories, OEM partners, distributors, and government organizations.
How is the cabinet packed for shipment?
Each cabinet is securely packed using protective industrial packaging, while export shipments are supplied in reinforced wooden crates to ensure safe transportation.
What is the expected delivery time?
Delivery depends on chamber size, customization requirements, optional accessories, and order quantity. Standard models are generally available with shorter production schedules than customized versions.
Call to Action
Looking for a reliable Horizontal Laminar Air Flow Cabinet for your laboratory, pharmaceutical facility, biotechnology center, university, or research institute? Opxica offers premium HEPA-filtered clean air workstations with multiple chamber sizes, customizable configurations, and competitive bulk pricing. Contact our team today to request a quotation or discuss your laboratory clean-air requirements.




